Process odorant meter AnOd

Process explosion proof odorimeter should be installed on existing and new gas distribution stations and units after odorization station. The most promising is installation of odorimeter in automated gas distribution stations and points, based on principles of fully automated technologies. Odorantmeter perfectly suits the principals of automation as it is able to control the functioning of odorization station based on measured concentration of odorant inside the pipe.


  • Control of ammount of odorant in natural gas and odorization unit functioning

Purpose

On-line measurement of mass concentration of mercaptains with calculation of concentration of mercaptan sulfur in natural gas

Features

Automatic operation

AnOd is operating without operator presence during verification period without requiring maintenance, adjustment, calibration mixtures or other gases. You don't need a permanent connection to the PC. All operations are performed by integrated microcomputer.

Automatic calibration

The stated accuracy of the analysis is achieved through regular automatic calibration using integrated source of microflow of ethyl mercaptan.

Communication

Analysis results are stored in the internal non-volatile memory device and displayed on the integrated LCD display and can be transmitted to remote PC or an automated control system using the RS485 / RS232 interface, 4-20 mA, Ethernet, wireless connections.

Easy installation

Compact explosion proof enclosure of the analyzer can be easily mounted directly on the pipe after odorization system at GDS, without requiring additional heating or placing in the block box.

Low life cast

The device does not require regular maintenance, no additional gases are required, has low power consumption and can operate in a wide temperature range: -40 to + 50 ° C

Specification:

Operating principle:

Electro-chemical

Measuring range, mg/m3

0-100 by mercaptains

Measuring range, мг/м3

0-50 by mercaptains sulphur

Accuracy, %

range 0-10 mg/m3

±25 (±20) full scale

range 10-100 мг/м3

±25 (±20) full scale

Cycle time, min

from 5

BACS - Bureau of Analiytical Complexes and Systems
COMPANY

About Company
Contacts
ENGINEERING

Design
Realization
AUTOMATION

Automation
SYSTEMS: GAS

Gas metering stations
Gas quality control systems
Automated gas distribution station
Gas distribution station
Gas analysis systems
Sampling systems
EQUIPMENT

Process chromatograph MAG
Process chromatograph PGC90.50
Portable chromatograph (sulphur, mercaptains)
Portable oxygen analyzer
Process analyzer H2S and CO2
Process odorant meter AnOd
Process oxygen analyzer AnOx
Coriolis flowmeter MIR
BLOCK-BOXES

Technological and operator's block-boxes
Modular laboratories
||||||||||||||||||||||||||||